Parmoon Information Technology Company (PITC) is established in 2005 with two departments: ICT and Industrial Automation departments.
About us

Activity Areas
Design, Consultation and Implementation of industrial automation systems and ICT Projects. more…

PITC
Parmoon Information Technology Company (PITC) is established in 2005 with two departments: ICT and Industrial Automation. more…

Mission
The general PITC Mission is to produce, implement and support products and services in ICT, Electrical and electronics engineering and industrial automation areas more…

Vision
Providing the high quality products and services using advanced technologies. more…
Products

Industrial Modem Serial to Net
The PM-1809 Converter is an industrial Modem capable of converting data form serial port to network and vice versa.It has seven RS485 ports and one RS232 port that converts information from various media such as GPRS, Wi-fi, Ethernet to serial port vice versa.the serial industrial modem prodused by Parmoon Group is resistant to noise emitting and EMC. more

Data Concentrator Unit(DCU)
Data Concentrator Unit (DCU) is an intelligent system to collect and monitor power networks. DCU is designed for data integrating, smart metering and monitoring. DCU includes important features such as high reliability, high availability, and data recovery after disconnecting using backup systems, ability to repair during routine tasks, high security, data integrity and fast response time. In addition to mentioned advantages, network parameters control, smart meters monitoring, remote warning system, awareness of the latest situation, prevent of sending teams to different areas, reduced maintenance costs and also reduced costs related to staffing could be mention. DCU is a hardware / software system, designed by PITC group and it is fully able to support SCADA standards and protocols such as DLMS / COSEM, MODBUS, DNP3, IEC101 / 104 and MULTIDROP REGISTER. The related software has different capabilities and is designed according to electrical and power industries standards. more

Digital Output Module
-Having 24V power supply
-Data transmission via network cable
-Ability to control 4 relays
-Having 4 analog outputs, 4 to 20 mA current
-Ability to change device parameters via the LAN port
-Ability to change the device settings by application
-Ability to Support MODBUS, DNP3, IEC101/104, TCP Protocols

Analog output module mA4-20
-Having 24V power supply
-Data transmission via network cable
-Having 4 analog outputs, 4 to 20 mA current
-Ability to change device parameters via the LAN port
-Ability to change the device settings by application
-Ability to Support MODBUS, DNP3, IEC101/104, TCP Protocols

Sensor Node
Sensor Node (Model pwsn-1031)
– Capability of connection to five analogue Sensors,
– Capability of connection to five digital Sensors,
– Having eight digital outputs
– Maximum range of coverage up to 2km outdoor, 300m indoor
– Capability of using up to 65535 sensor nodes in WSN
– Capability of Error Detection and Correction
– Four different working frequencies: 2.4GHz, 433 MHz, 868MHz, 915MHz
– Rechargeable Battery with Adaptor & Photo cell
– Connection capability to measurement device to display the information
– IP-based with addressing capability
– Programmable with different modes using personal computer
– Capability of coverage range adjustment
– Supporting 802.15.4 protocol- Maximum Battery usage up to 120 days before recharging

Base Station Module
– Capability of connection up to 65535 sensor nodes
– Four different working frequencies: 2.4GHz, 433 MHz, 868MHz, 915MHz
– Capability of connection to personal computer using USB port
– Maximum range of coverage up to 2km outdoor, 300m indoor
– Capability of Error Detection and Correction
– Having 12V adaptor
– Having touch color LCD to display the information or drawing

Portable Measurement Unit
-Capability of parameter measurement for sensor nodes
-Drawing graphs for sensor nodes using color LCD
-Measuring receive data rate of sensor nodes
-Measuring transmit data rate of sensor nodes
-Measuring power consumption of sensor nodes
-Measuring battery voltage of sensor nodes
-Measuring status and output value of sensor nodes
-Measuring logic level of each output for sensor nodes
-Having Rechargeable Battery
catalog
Please Click Here to download Parmoon Group products anrvices brochures
Training Courses

ISMS
The purpose of this course is to acquaint managers and experts of organizations and companies with the main concepts of information security, the ......More

ISO Impelementation
In this training course, the audience will receive the necessary training on the creation, implementation, deployment and internal audit of the Information ......More

Risk assessment and management
The purpose of this course is to get acquainted with the best standards and methods of information security risk management based on ...More
Our customers

Contact us
Address: Emamjome st. Jomhoori Blvd, Kerman, Iran.
Tell: +983432466574
Fax: +983432466574
Postal Code: 7613999575